Filter price review or Delta Xero at your site?Book a meeting

Delta Xero unit installed next to a tank

Service from sizing to cartridge change

We size the unit from your tank and oil, install it on site and document the effect with samples before and after. After that, the cartridges are changed to a fixed plan. We carry out installation and service throughout Denmark.

What we deliver

  1. Sizing

    We choose the model from the size of the tank, oil or diesel, and how much is refilled. A diesel tank should pass through the filter about 2.5 times a month. See the sizing table or use the unit selector.

  2. Installation and commissioning

    We mount the unit on site and put it into operation. It runs in a kidney loop with a suction line from the bottom and the return above liquid level. The existing system stays as it is.

  3. Sampling programme

    We take samples before, during and after. They are analysed in an independent laboratory for particles, water and, on diesel, bacteria and fungi.

  4. Report with graphs

    You get the figures before and after in a report with graphs of cleanliness code and water content, so the improvement can be shown internally and compared over time.

  5. Cartridge subscription

    Cartridges are delivered at fixed change intervals, so the change is not forgotten. The interval is adjusted once the used cartridges have been analysed.

  6. Pilot programme

    If you want to see the figures on your own system first, you can apply for an 8-week pilot. Read about the pilot programme.

Change intervals

Older tanks often hold bottom sludge and water from many years of operation. That is why the cartridge is changed more often in the first year.

ApplicationFirst yearAfter that
Diesel, new tankevery 6 monthsevery 6 months
Diesel, older tankevery 4 monthsevery 6 months
Oil: hydraulic, gear and enginefrom the samplesfrom the samples
The interval can be extended once the used cartridges have been analysed.

Samples are analysed by POLARIS Laboratories

Samples before and after are analysed by POLARIS Laboratories, an independent oil laboratory, and results arrive within a few days. Samples can also be tested at Delta Xero in England.

What we measure

ISO 4406
Particles per ml at 4, 6 and 14 µm, given as a cleanliness code, e.g. 18/16/13.
Karl Fischer
Water content in ppm. Diesel may contain no more than 500 ppm.
MPC
Varnish potential: how much lacquer the oil can deposit in the system.
Micropatch
The oil is filtered through a membrane so that wear particles and dirt can be seen and photographed.
Bacteria and fungi
Test for diesel bug in fuel, with the result given as FAIL or PASS.
Oil sample being analysed in a laboratory

What customers say

The statements are shown with name and title as they appear in the case material.

“Since we have installed the filtration unit at Biffa we have not had any fluid related issues that we have been made aware of. Prior to the system being installed we had replaced three hydraulic pumps and various valves. As the machine was under warranty this cost impacted us directly, for both parts and labour, at a cost of around £15,000.”

Ben CleggService Manager, Whitham Mills (the baler's manufacturer)Read the case

“Since fitting Delta-Xero systems our crane downtime has reduced significantly and the life of our filters has been extended three-fold. The higher quality of fuel and oil gives health and environmental benefits.”

Robert ScribbinsEngineering Manager, Portico Shipping LtdRead the case

“It turns out they (Delta Xero) were correct; the filter can rapidly eliminate contaminants, including varnish, that SFF and purification methods cannot.”

Fleet technical manager at the operatornot named in the distributor's material (Hexagon Europe)Read the case

“After owning and operating this turbine for many years, we have never seen the gearbox look so clean. It is in pristine condition.”

The turbine ownerMacrete Ireland Ltd (name not given in the source)Read the case

Questions about service

Who installs the unit?

We do. We install and service the units on site throughout Denmark. The unit is connected to the tank or system with a suction line and a return line, and the existing system stays as it is.

Where are the samples analysed?

At POLARIS Laboratories, an independent oil laboratory. Results arrive within a few days. Samples can also be tested at Delta Xero in England.

How often does the cartridge need changing?

On diesel in new tanks every 6 months. In older tanks every 4 months in the first year and every 6 months after that. On oil, the interval is set from the samples. The interval can be extended once the used cartridges have been analysed.

Can we try it before we buy?

Yes, through the pilot programme: 8 weeks on your own system with samples before, during and after, and a short report with the figures.

What do your oil changes cost?

Enter your own figures. The calculator adds no assumptions apart from the reduction in oil changes that you choose on the slider.

Enter litres per change, changes per year and oil price to see the calculation.

Example: Enovert went from about 48 to 7 oil changes a year. Read the case study.

The figures stay in your browser and are not sent anywhere. We measure the real figure for your system with samples before and after in a pilot programme. How the pilot programme works.