Filter price review or Delta Xero at your site?Book a meeting

Offshore wind turbines
Wind turbines

Bonus 300 kW: new gear oil was black after 19 days, 51 days later it was clean

The gearbox in a ten-year-old Bonus turbine was drained, flushed and refilled with new oil, but 19 days later the oil was already dark. After 51 days with a DX1525 the oil and the membrane patch were clean, and at the annual inspection the owner described the gearbox as pristine.

Oil appearance

dark 19 days after the oil changevisibly clearer after 51 days
19 daysbefore the new oil was dark again after flushing
51 daysfrom installation to clean oil and a clear membrane patch
80 litresof gear oil cleaned by a 13 kg DX1525
CustomerMacrete Ireland Ltd
CountryNorthern Ireland (Toomebridge)
System80-litre three-stage gearbox in a 300 kW Bonus wind turbine, Delta Xero DX1525-SV
FluidMineral gear oil, ISO VG 320

Macrete Ireland Ltd runs a 300 kW Bonus wind turbine that supplies power to its precast concrete factory. The turbine’s three-stage gearbox is ten years old and holds 80 litres of gear oil. Despite regular servicing, the oil was dark and there were deposits inside the gearbox.

On 5 September 2023 the gearbox was drained, flushed and refilled with new mineral gear oil, ISO VG 320. Only 19 days later the new oil was already dark. Residual sludge and varnish from the gearbox surfaces had contaminated it again. The 0.45 µm membrane patch was heavily contaminated, and metallic debris was visible under the microscope.

On 24 September 2023 a DX1525-SV was fitted and ran the oil through the cartridge continuously, with no chemical additives and no oil cooling.

After 51 days the oil was visibly clearer, the membrane patch was clear, and the metallic debris was gone from the sample. The gearbox housing and components also showed less sludge and varnish. At the annual inspection one year after installation, the housing, gears, shafts and bearing surfaces were visibly cleaner, with nothing else done to clean them.

The figures before and after

MeasurementBeforeAfter
Oil appearancedark 19 days after the oil changevisibly clearer after 51 days
Membrane patch 0.45 µmheavily contaminatedclear
Metallic debris under the microscopevisiblenone in the sample
Gearbox internalssludge and varnish on housing and gearsvisibly cleaner after 1 year with no other cleaning

“After owning and operating this turbine for many years, we have never seen the gearbox look so clean. It is in pristine condition.”

The turbine owner, Macrete Ireland Ltd (name not given in the source)

Read the full case study

The rest of the case study, with every before and after measurement, opens once you have entered your work email and company. You only need to do this once; then every case study on the site is open.

We only use the details to see which companies are reading. You will not receive newsletters, and we will not call you.