Filter price review or Delta Xero at your site?Book a meeting

Production hall with machine line
Manufacturing and industry

ORE Catapult: over 24 kg of sludge out of the hydraulic oil despite a 3 µm inline filter

The hydraulic oil on ORE Catapult's test rig was full of particles, varnish and carbon, even though the system had a 3 µm inline filter. Offline filtration removed over 24 kg of sludge and debris in six months, interventions and downtime fell by 80 to 85 %, and ORE Catapult has since bought a second unit.

Sludge, varnish and debris removed in 6 months

in the oil despite a 3 µm inline filterover 24 kg removed
80 to 85 %fewer technical interventions and less downtime
over 24 kgof sludge, varnish and debris removed in six months
under 2 weeksestimated payback according to ORE Catapult
CustomerORE Catapult
CountryUnited Kingdom (Fujin test facility)
SystemLarge hydraulic power unit (HPU) on a wind industry test rig, Delta Xero DX1006-T-MP-VFD
FluidHydraulic oil

ORE Catapult is the UK’s research and test centre for offshore wind and other renewable energy. At its Fujin test facility there is a large test rig with a hydraulic power unit (HPU). The oil was contaminated with particles, varnish, burnt carbon and aluminium debris, and there were signs of electrostatic discharge. This put sensors, actuators, strainers and filters at risk. The HPU already had a 3 µm inline filter.

First, a controlled trial ran on site: 25 litres of the oil were cleaned for about 23 hours with a mobile DX1001-T-MP-VFD. The oil was cold, 13 to 20 °C, so the flow was only about 0.2 litres per minute. Samples were taken before, after four hours and after about 23 hours. After four hours the particle count had fallen and the membrane patch was visibly cleaner. After about 23 hours the patch was clear, and the customer’s own particle counter showed almost the same figures as ours.

Independent laboratories checked viscosity and additives and found no detrimental effect. ORE Catapult then bought a permanent DX1006-T-MP-VFD for the HPU. In the first six months it removed over 24 kg of sludge, varnish and debris. ORE Catapult reports that technical interventions and downtime have fallen by 80 to 85 % and estimates the payback at under two weeks. The customer has since bought a second unit.

The figures before and after

MeasurementBeforeAfter
Sludge, varnish and debris removed in 6 monthsin the oil despite a 3 µm inline filterover 24 kg removed
Technical interventions and downtimebaseline80 to 85 % fewer
Membrane patch 0.45 µm in the trialblackclear after about 23 hours
Viscosity and additivesnew oilno detrimental effect (independent laboratory)