GE wind turbine fleet: 91.5 % fewer particles in the gear oil across 28 gearboxes

After the trial on four turbines, the operator rolled offline filtration out across its fleet of GE turbines. After about 18 months, particles above 4 µm were down 91.5 % on average across 28 gearboxes, and around 150 units were in service.

Particles above 4 µm per ml, average of 28 gearboxes

11,100947
91.5 %fewer particles above 4 µm on average across 28 gearboxes
about 150units in service across the fleet
117 turbinesin the fleet, where the trial started on four
CustomerUK operator of GE 1.5 and 1.6 MW wind turbines (not named in the source)
CountryUnited Kingdom
SystemGearboxes of about 350 litres in GE 1.5 and 1.6 MW wind turbines, Delta Xero DX1001-W and DX1525
FluidSynthetic gear oil, ISO VG 320

The operator has 117 GE 1.5 MW wind turbines. The gear oil was changed about every four years, and oil changes and flushing cost oil, labour and downtime. The routine oil analyses did not show how much sludge, varnish, water and wear debris was actually sitting in the gearboxes.

On 18 August 2022, DX1525 and DX1001-W units were fitted to four turbines that were 15 to 16 years old. Oil was drawn from the lowest point of the gearbox and returned above the fill level. The first cartridges were full after 60 days because they had collected settled debris. After 120 days the oil was visibly clearer, the membrane patches showed no varnish, and viscosity and additives were still in good order. The trial is described in the case study on the four GE turbines.

Filtration was then extended to the fleet of GE 1.5 and 1.6 MW turbines. After about 18 months, 28 gearboxes were measured. On average, particles above 4 µm had fallen from 11,100 to 947 per ml, 91.5 %, particles above 6 µm by 86.6 % and above 14 µm by 72.8 %. That is 4, 3 and 2 ISO classes better. Around 150 units are in service across the fleet.

A cartridge that had been in service for about 11 months contained about 3.8 kg of debris. Its analysis is in the case study on the contents of the filter cartridges.

The figures before and after

MeasurementBeforeAfter
Particles above 4 µm per ml, average of 28 gearboxes11,100947
Particles above 6 µm per ml, average1,573211
Particles above 14 µm per ml, average62.817.1
Improvement in ISO classes (4, 6 and 14 µm)baseline4, 3 and 2 classes better